E18
Severin Stuck Relay / Control Output Fault

Microwave shows E18; interior light and fan may run continuously until unplugged.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded relay contacts on PCB, Shorted triac (if used), Control board logic failure, Moisture or contamination on PCB

How to Fix / Troubleshooting

Safety first: Disconnect from mains before opening the control panel.

  • Step 1 – Observe behavior: Note which components run continuously (fan, light, turntable). This helps identify which relay may be stuck.
  • Step 2 – Inspect control PCB: Remove the control panel and examine the board for signs of overheating around relays or triacs.
  • Step 3 – Clean contamination: If you see grease or moisture on the PCB, carefully clean with isopropyl alcohol and a soft brush, then allow to dry completely.
  • Step 4 – Replace PCB or relay: If a relay is welded closed, it must be replaced. Most users will replace the entire control PCB for reliability.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control PCB
Check Price on Amazon

We may earn a commission from links on this page.