E19
Severin
Output Drive Failure / No Load Activation
Microwave displays E19; timer counts down but no heating or fan operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown output relay, Broken solder joint on relay, Faulty control microcontroller output, Open wiring to HV transformer
How to Fix / Troubleshooting
Safety first: Unplug the microwave before accessing internal components.
- Step 1 – Confirm symptom: Place a cup of water inside and start cooking. If the timer counts down but there is no sound of the transformer or fan, suspect an output drive issue.
- Step 2 – Inspect wiring: With the cabinet removed, check wiring from the control PCB to the HV transformer and fan. Ensure connectors are secure.
- Step 3 – Check relays: On the control PCB, identify the main power relay. Inspect for burn marks or cracked solder joints. Resolder if necessary.
- Step 4 – Replace control PCB: If the relay coil is not being energized or contacts are burnt, replace the relay or the entire PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Power Relay on Control PCB
Check Price on Amazon