E18
Vida Exhaust Fan Control Fault

Microwave shows E18 and the exhaust fan on an over-the-range model does not operate or is stuck on high.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed exhaust fan motor, Stuck fan speed relay on control board, Loose fan wiring harness, Obstructed blower wheel

How to Fix / Troubleshooting

Safety: Turn off power at the breaker or unplug the unit before inspection.

Steps:

  • 1. Check fan settings: Cycle through fan speeds on the control panel to see if any setting works.
  • 2. Listen for noise: If the motor hums but the fan does not move air, the blower wheel may be jammed.
  • 3. Access blower (for DIYers): Remove the top grille and blower cover (per Vida instructions). Inspect the blower wheel for obstructions and ensure it spins freely.
  • 4. Wiring: Check that the fan motor connectors are secure.

If the motor is seized or open-circuit, replace the exhaust fan motor assembly. If the fan runs constantly regardless of settings, the control board relay is likely stuck and the board will need replacement.