Binatone
Keep Warm Temperature Too High
Keep Warm function overheats food, causing it to dry out or burn.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect temperature calibration on PCB, NTC sensor reading too low, Firmware bug, Poor heat dissipation due to blocked vents
How to Fix / Troubleshooting
Safety first: Unplug before internal inspection.
- Ventilation: Ensure the cooker vents are not blocked and there is adequate space around the unit.
- Reduce warm time: Manually limit the duration of KEEP WARM or turn it off when not needed.
- Sensor check (technician): Verify the NTC sensor is correctly mounted and not contaminated with thermal paste or debris that could skew readings.
- PCB replacement: If keep‑warm temperatures remain excessive, replace the main control PCB with the correct Binatone part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements