Possible Causes

Damaged float valve silicone gasket, Debris under float valve seat, Incorrectly installed float valve pin

How to Fix / Troubleshooting

Safety first: Turn off and unplug the cooker. Allow it to depressurize naturally before servicing the float valve.

  • Disassemble float valve: Remove the retaining pin or clip and take out the float valve and silicone gasket.
  • Clean components: Wash the valve and gasket thoroughly. Clean the valve seat in the lid with a cotton swab.
  • Inspect gasket: Replace the silicone gasket if it is worn, cracked, or hardened.
  • Reassemble: Reinstall the float valve in the correct orientation and secure the retaining pin.