E8
Klarstein Pressure Not Reached / Leak Detected

E8 error appears, often accompanied by failure to build pressure or premature end of cooking.

Advertisements

Possible Causes

Damaged silicone sealing ring, Worn or dirty float valve gasket, Steam release valve stuck in venting position, Cracked lid or deformed inner lid plate

How to Fix / Troubleshooting

Safety: Allow the cooker to cool and depressurize before inspecting the lid components.

Step 1 – Inspect sealing ring:

  • Remove the inner lid (if applicable) and take out the silicone sealing ring.
  • Check for cracks, hardening, or deformation. A loose or stretched ring will leak steam.
  • Clean the ring and the groove in the lid with warm soapy water, then dry thoroughly.

Step 2 – Check valves:

  • Remove the steam release valve and clean it; ensure it moves freely between sealing and venting positions.
  • Inspect the float valve and its small silicone cap; replace if cracked or stiff.

Step 3 – Visual leak check:

  • Run a short pressure program with only water.
  • Observe the lid area for escaping steam around the ring, valves, or hinge.

Step 4 – Repair:

  • Replace the silicone sealing ring if it shows any damage or if it is more than 1–2 years old.
  • Replace worn float valve gasket and steam release valve as needed.
  • If the lid or inner lid plate is cracked or warped, replace the complete lid assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Silicone Sealing Ring
Check Price on Amazon

We may earn a commission from links on this page.