E5
Sage Pressure Sensor Fault / Pressure Not Detected

E5 error appears when trying to start a pressure program; cooker does not build pressure.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked pressure sensor port, Faulty pressure transducer, Loose pressure sensor wiring connector, Control board pressure circuit fault

How to Fix / Troubleshooting

Safety first: Ensure the cooker is unplugged and fully depressurized before inspection.

  • Clean steam release components: Remove and clean the steam release valve, anti-block shield, and float valve cap according to the user manual. Starch buildup can affect pressure sensing.
  • Check float valve movement: Ensure the float valve moves freely up and down and is not stuck by dried food. Clean and reassemble.
  • Inspect pressure sensor tube (if accessible): Some Sage multicookers have a small tube or channel from the lid to the pressure sensor. If accessible, ensure it is not blocked with residue.
  • Reset the cooker: After cleaning, plug the unit back in and try a simple pressure program with adequate liquid.
  • When to replace: If E5 persists, the pressure sensor module or its wiring is likely defective and should be replaced. This involves opening the lid or top housing and is best done by a technician.