F19
Fulgor Milano
Non‑Volatile Memory or Configuration Error
Oven shows a power failure or reset error after outages; may require reprogramming.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted EEPROM on control board, Sudden power loss during operation, Firmware bug, Failing control board memory
How to Fix / Troubleshooting
Safety first: No internal access is needed for initial steps. Disconnect power before any board replacement.
- 1. Clear error: Follow the display prompts to clear the power failure message. Set the clock and test oven functions.
- 2. Power cycle: If the error reappears immediately, turn off the breaker for 10 minutes, then restore power.
- 3. Factory reset: Some Fulgor Milano models allow a factory reset from the settings menu. Perform a reset if available and reconfigure basic settings.
- 4. Board replacement: If configuration cannot be saved or the error persists after resets, the non‑volatile memory on the control board is likely failing. Replace the main control board with the correct model‑specific part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements