F19
Fulgor Milano Non‑Volatile Memory or Configuration Error

Oven shows a power failure or reset error after outages; may require reprogramming.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM on control board, Sudden power loss during operation, Firmware bug, Failing control board memory

How to Fix / Troubleshooting

Safety first: No internal access is needed for initial steps. Disconnect power before any board replacement.

  • 1. Clear error: Follow the display prompts to clear the power failure message. Set the clock and test oven functions.
  • 2. Power cycle: If the error reappears immediately, turn off the breaker for 10 minutes, then restore power.
  • 3. Factory reset: Some Fulgor Milano models allow a factory reset from the settings menu. Perform a reset if available and reconfigure basic settings.
  • 4. Board replacement: If configuration cannot be saved or the error persists after resets, the non‑volatile memory on the control board is likely failing. Replace the main control board with the correct model‑specific part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Electronic Control Board
Check Price on Amazon