F9
Gorenje Power Supply / Line Voltage Fault

Display shows F9 and oven functions are disabled; may occur after a short circuit or wiring issue.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect mains connection (phase/neutral reversed or missing), Loose terminal block connections, Damaged power filter board, Internal short on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the main breaker. Only perform electrical checks if you are competent and local regulations allow; otherwise contact a licensed electrician.

  • Verify supply voltage: Confirm that the oven is connected to the correct mains voltage and phase configuration as specified on the rating plate (e.g., 230 V single-phase). Incorrect wiring can trigger F9.
  • Inspect terminal block: Remove the rear cover to access the mains terminal block. Check for loose screws, burned insulation, or melted plastic. Tighten connections and replace any damaged parts.
  • Check power filter / interference suppressor: Inspect the EMI filter module for burn marks or bulging components. Replace if damaged.
  • Control board inspection: Look for obvious shorts or burned tracks on the control board. If found, the board must be replaced.
  • Restore power and test: After correcting wiring and replacing any damaged components, restore power and test. If F9 persists, a deeper control board fault is likely and professional service is recommended.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Mains Terminal Block
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements