F9E0
Monogram Configuration or communication error between user interface and control

F9E0 error; oven will not start and may indicate a communication or configuration problem

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrectly configured control board, Loose UI-to-main-board harness, Failed user interface board, Failed main control board

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing internal components.

  • Power reset: Turn off the breaker for 5 minutes, then restore power. Sometimes configuration errors clear after a full reset.
  • Check harness connections: Remove the control panel and verify that the multi-pin harness between the user interface board and the main control board is fully seated and not damaged.
  • Inspect for moisture: Look for signs of steam or moisture intrusion around the UI board. Dry thoroughly and improve door gasket seal if needed.
  • Reconfigure (if applicable): Some Monogram models require configuration codes to be entered on a new control board. Verify that the correct model configuration is set according to the tech sheet.
  • Replace faulty board: If wiring is good and configuration is correct but F9E0 persists, replace the user interface board. If that does not resolve it, replace the main electronic control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

User Interface Board
Check Price on Amazon