E16
Tower
Stuck Cooling Fan Control / Relay
Oven shows E16 and the fan runs continuously even when the oven is off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck cooling fan relay on control PCB, Shorted triac, Misreading temperature sensor causing board to think oven is hot, Wiring short keeping fan energized
How to Fix / Troubleshooting
Safety first: Turn off power before removing panels.
Steps to check:
- Temperature check: Ensure the oven is actually cool. If it is still hot, the fan may be running correctly until the cavity cools.
- Sensor reading: Test the cavity temperature sensor resistance at room temperature. If it reads as if the oven is hot, replace the sensor.
- Control board: If the sensor is normal, the cooling fan relay or triac on the control board may be stuck closed. In this case, the main control PCB will need replacement.
Note: A continuously running fan is usually not dangerous but indicates a control fault that should be corrected to avoid premature fan wear.
Advertisements
Repair Difficulty
Hard