V-ZUG
Temperature Regulation / Calibration Error
Oven heats but temperature is significantly too low or too high compared to the set value; no error code shown.
Advertisements
Possible Causes
Aging or drifting NTC temperature sensor, Poor contact at sensor connector, Incorrect user calibration offset, Faulty control algorithm on PCB
How to Fix / Troubleshooting
Safety first: Ensure the oven is installed correctly and not exposed to extreme ambient temperatures.
Step-by-step checks:
- Verify with thermometer: Place an accurate oven thermometer in the center of the cavity and compare actual temperature to the set value over several cycles.
- Adjust offset: Use the settings menu to adjust the temperature offset (if available) according to the user manual.
- Inspect sensor: Check that the NTC sensor is firmly fixed in its bracket and not touching the heating elements. Reseat its connector on the control board.
- Replace sensor: If readings are erratic or far off, replace the V-ZUG temperature sensor.
When to call a technician: If calibration and sensor replacement do not resolve the issue, the control board may require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Oven Temperature Sensor (NTC Probe)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements