E41
Wolf Stuck Relay or Output Error

Wolf oven shows E41 and fan or elements may continue running after cycle ends.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded relay contacts on control or relay board, Shorted triac, Control board logic failure, Incorrect wiring after previous repair

How to Fix / Troubleshooting

Safety: Turn off power at the breaker immediately if elements or fans run uncontrollably.

Inspection:

  • Access the relay/power board and inspect for burnt or welded relay contacts.
  • Check wiring against the Wolf wiring diagram to ensure correct connections.

Corrective actions:

  • Replace the relay/power board or main control board if any relay is stuck closed.
  • After replacement, test all functions to ensure elements and fans cycle correctly.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Relay / Power Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements