ERR9
Gourmet Grillson
Combustion Fan Circuit Fault
Display shows ERR9 and grill will not start; fan briefly spins then stops.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed combustion fan motor, Obstructed fan blade, Loose fan wiring connector, Burned fan driver on control board
How to Fix / Troubleshooting
Safety first: Unplug the grill before accessing the fan compartment.
- Access fan: Remove the rear or side service panel to expose the combustion fan assembly.
- Check for obstructions: Inspect the fan blades for grease buildup, foil, or debris. Clean thoroughly and ensure the blade spins freely by hand.
- Inspect wiring: Verify the fan motor connector is fully seated on the harness and that wires are not pinched or burned.
- Test fan motor: With the fan disconnected, use a multimeter to check for appropriate resistance across the motor leads (not open). If available, briefly power the fan with a suitable test source to confirm operation. Replace the fan motor if it does not spin.
- Check board output: If a known-good fan does not run when the grill is started, the fan driver circuit on the control board may be failed. Replace the main control board.