Espa Impeller Damage or Loose Components

Pump makes a rattling or clattering noise from the wet end during operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken impeller vanes, Loose impeller on shaft, Foreign object inside volute, Cracked diffuser

How to Fix / Troubleshooting

Safety first: Turn off power and close isolation valves before opening the pump.

  • 1. Inspect pump interior: Remove the pump lid and basket, then disconnect unions and separate the pump housing from the motor to access the impeller.
  • 2. Remove foreign objects: Take out any stones, screws, or other debris that may be striking the impeller.
  • 3. Check impeller tightness: Ensure the impeller is firmly threaded onto the motor shaft. Tighten gently by hand while holding the shaft at the rear (per Espa instructions).
  • 4. Replace damaged parts: If impeller vanes or the diffuser are cracked or broken, replace them with genuine Espa parts to avoid imbalance and further damage.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Espa impeller / diffuser