Espa

Espa Pool Pumps Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Pump does not start, digital controller shows E01 immediately after power-on
Motor Overload / Overcurrent Protection Triggered
E02
Pump stops during operation and displays E02 on the Espa digital controller
Thermal Overload / Motor Overheating
E03
Espa variable-speed pool pump will not start and shows E03 on the display
Phase Loss / Supply Voltage Fault (Three-Phase Models)
E04
Espa variable-speed pump display shows E04 and the motor will not run
Dry-Run Protection / No Water Flow Detected
E05
Espa pump controller shows E05 and stops shortly after starting
Overpressure / Blocked Discharge Line
E06
Espa variable-speed pump shows E06 and will not run at higher speeds
Overcurrent at High Speed / Impeller or Hydraulic Overload
E07
Espa pump controller displays E07 and the motor hums but does not start
Start Capacitor Failure (Single-Phase Models)
E08
Espa variable-speed pump shows E08 and stops intermittently
Internal Drive Overtemperature / Electronics Overheating
E09
Espa pump controller shows E09 and refuses to start after a power surge
Internal Electronics Fault / Control PCB Error
E10
Espa pump display shows E10 and the motor stops abruptly
Ground Fault / Earth Leakage Detected
E11
Espa variable-speed pump shows E11 and cannot communicate with external controller
Communication Error (RS-485 / External Control Link)
E12
Espa pump controller displays E12 and the pump speed fluctuates erratically
Speed Feedback / Sensor Error
E13
Espa pump shows E13 and will not start after being wired for a different voltage
Incorrect Supply Voltage / Configuration Error
E14
Espa pump controller intermittently shows E14 and stops when rainwater enters the housing
Low Control Voltage / Auxiliary Power Fault
E15
Espa pump display shows E15 and the keypad does not respond
Keypad / User Interface Error
Symptom
Pump emits a burning smell and the motor casing is extremely hot to the touch
Severe Motor Overheating / Insulation Breakdown
Symptom
Pump hums but does not start, then trips the breaker after a few seconds
Locked Rotor / Failed Start Circuit
Symptom
Pump is unusually quiet and cool but there is no water flow (motor may not actually be running)
Control Logic / Relay Failure
Symptom
Pump is very noisy, with a loud grinding or screeching sound from the motor end
Motor Bearing Failure
Symptom
Pump loses prime after a few minutes of operation, basket slowly empties and pump sucks air
Suction Air Leak / Inadequate Net Positive Suction Head
Symptom
Pump makes a rattling or clattering noise from the wet end during operation
Impeller Damage or Loose Components
Symptom
Pump motor runs but the impeller does not turn, no water movement
Shaft Coupling / Impeller Drive Failure
Symptom
Pump runs but filter pressure is higher than normal and return jets are weak
High System Backpressure / Filter Restriction
Symptom
Pump runs but flow is weak and filter pressure is lower than normal
Reduced Hydraulic Performance / Partially Blocked Impeller
Symptom
Pump runs but makes a cavitation noise (gravelly, crackling sound) and flow is unstable
Cavitation Due to Inadequate Suction Conditions
Symptom
Pump runs but overheats and shuts off after 10–20 minutes, then restarts after cooling
Thermal Overload Cycling
Symptom
Pump runs but there is a constant stream of air bubbles from the pool return jets
Air Ingress on Suction Side
Symptom
Pump runs but there is no water flow, pump basket does not fill with water
Loss of Prime / Air Ingress on Suction Side
Symptom
Pump runs but water appears cloudy and filtration seems ineffective despite normal pressure
Insufficient Circulation Time or Low Flow Rate
Symptom
Pump speed fluctuates up and down without user input on a variable-speed Espa pump
Unstable Control Input / Sensor Interference
Symptom
Pump starts normally but stops when the pool cleaner line is opened
Excessive Suction Load / Flow Restriction
Symptom
Pump trips the circuit breaker or RCD immediately when switched on
Electrical Short or Earth Leakage
Symptom
Pump vibrates excessively and moves on its base during operation
Imbalance or Poor Mounting
Symptom
Pump will not restart automatically after a power outage, requires manual reset
Auto-Restart / Control Logic Configuration
Symptom
Pump will not start at all, no humming, no display, Espa pool pump appears completely dead
No Power to Pump / Open Circuit
Symptom
Water leaking between the motor and the pump housing under the Espa pump
Mechanical Seal Failure
Symptom
Water leaking from the clear pump lid area when the pump is running
Lid Seal Failure / Cracked Lid
Symptom
Water leaking from the drain plugs at the bottom of the Espa pump housing
Drain Plug Seal Failure
Advertisements