Jacuzzi
System Overpressure / Filter Restriction
Pump runs but filter pressure is unusually high and flow at returns is weak.
Advertisements
Possible Causes
Dirty or clogged filter, Closed return valves, Undersized plumbing, Partially closed heater bypass
How to Fix / Troubleshooting
Safety first: Turn off pump before adjusting valves or opening the filter.
Steps to correct:
- Backwash or clean filter: For sand or DE filters, perform a full backwash. For cartridge filters, remove and hose off or replace cartridges.
- Open valves: Ensure all return-side valves are fully open.
- Check heater bypass: Verify that any heater bypass or check valves are in the correct position and not restricting flow.
- Monitor pressure: Restart the Jacuzzi pump and note the clean filter pressure. Mark this as a reference for future maintenance.
If pressure remains high with a clean filter, consult a professional to evaluate system design and plumbing restrictions.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements