Pump will not start, display shows E01 immediately after pressing START
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off the circuit breaker feeding the pump and verify power is off with a meter before opening any covers.
- Check supply voltage: Using a multimeter, measure voltage at the pump input terminals (L–N). For most Saci single‑phase pool pumps this should be around 230 V AC. If it is below the rated range (e.g. < 207 V), contact an electrician or your power provider.
- Inspect wiring connections: Remove the electrical cover on the Saci pump motor. Tighten all terminal screws on L, N and Earth. Look for discoloration or melted insulation that indicates overheating.
- Remove extension cords: If the pump is connected via a long or thin extension cable, connect it directly to a properly rated, dedicated circuit to reduce voltage drop.
- Reset the drive: After correcting the supply, turn the breaker back on, wait 30 seconds, then press START on the pump controller to clear E01.
If E01 persists with correct voltage, the internal control board may be misreading voltage and should be checked by a technician.
Repair Difficulty
Required Part
We may earn a commission from links on this page.