E15
Saci
Priming Failure / Dry‑Run Protection
Pump shows E15 and cannot detect priming, shuts down after a short run
Advertisements
Possible Causes
Air leak on suction side, Pump installed above water level without proper priming, Low water level in pool, Blocked suction line or skimmer
How to Fix / Troubleshooting
Safety first: Turn off power before opening the pump lid or valves.
- Check water level: Ensure the pool water level is at least halfway up the skimmer opening so the skimmer does not draw air.
- Prime the pump: Close suction and return valves. Remove the Saci pump lid, fill the strainer housing completely with water, replace the lid, then open valves.
- Inspect for air leaks: Check the pump lid O‑ring for cracks or dirt; clean and lubricate with silicone grease. Tighten unions on the suction side and inspect for cracks in fittings.
- Clear suction line: Remove skimmer basket and any suction‑side cleaners. Use a hose or plumbing snake to clear obstructions if flow is restricted.
After correcting issues, restart the pump and watch for a solid water flow. If E15 continues, the dry‑run sensor or control logic may be faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Pump Lid O-Ring
Check Price on Amazon