F2
AEG
Flame Supervision Device (FSD) / Thermocouple Fault
AEG gas hob shows F2, burners shut off automatically
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty or misaligned thermocouple, Weak flame not heating sensor, Faulty thermocouple, Faulty gas safety valve
How to Fix / Troubleshooting
Gas safety: Ensure good ventilation. Turn all burners off before working near them.
User checks:
- Remove burner caps and clean the thermocouple tip (small metal rod near the burner) with a soft brush to remove grease and carbon.
- Reassemble burners correctly and ensure the flame fully envelops the thermocouple when lit.
- Test by lighting the burner and holding the knob in for the recommended time (usually 5–10 seconds) before releasing.
If F2 persists on a specific burner:
- The thermocouple or associated gas valve may be defective.
- Replacement involves disconnecting gas lines and should be performed by a certified gas technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Burner Thermocouple
Check Price on Amazon