E41
Amica
Low Voltage / Power Supply to Control Board
Electric range shows E41 and the clock/timer functions erratically or reset themselves.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose neutral connection, Faulty internal power supply on control board, Intermittent mains supply, Damaged wiring harness
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before accessing wiring.
- Check terminal block: Inspect the main terminal block at the rear of the range for loose or burned connections, especially the neutral. Tighten or replace as needed.
- Inspect harness: Follow the wiring from the terminal block to the control board. Look for pinched, burned, or broken wires and repair or replace.
- Measure supply: With power restored (qualified person only), measure voltage at the control board input. Ensure it matches the rating plate.
- Control board replacement: If supply is stable but E41 persists and the display resets or flickers, the electronic control board power supply section is likely faulty and the board should be replaced.
- Re-test: After repairs, verify stable clock operation and that E41 no longer appears.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.