Amica Flame Failure Device Not Holding

Gas hob burner goes out when the knob is released, even though it lights initially.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak thermocouple, Misaligned thermocouple tip, Faulty flame failure valve, Poor grounding of hob

How to Fix / Troubleshooting

Safety first: Turn off gas before internal work. Gas repairs should be performed by qualified personnel.

  • Clean and align: Ensure the burner cap is correctly seated and ports are clean. The flame should fully envelop the thermocouple tip.
  • Hold longer: After lighting, keep the knob pressed for 10–15 seconds to allow the thermocouple to heat. If the flame still goes out, the thermocouple may be faulty.
  • Replace thermocouple: Replace the burner thermocouple for the affected burner, routing the new one as per the original.
  • Valve check: If a new thermocouple does not solve the issue, the gas safety valve may be defective and should be replaced by a gas technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Burner Thermocouple
Check Price on Amazon

We may earn a commission from links on this page.