Ariston Cooling Fan Control / Thermostat Stuck

Oven cooling fan runs continuously long after cooking has finished.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck cooling fan thermostat, Faulty control board fan relay, Shorted wiring causing permanent fan supply

How to Fix / Troubleshooting

Safety: Turn off power before removing panels.

  • Allow full cool-down: Some Ariston ovens keep the fan running until the cavity cools. Wait at least 30–60 minutes to see if it stops normally.
  • Check thermostat: Locate the cooling fan thermostat (often on the top of the oven). Test continuity when cold; it should be open. If it remains closed when cold, replace it.
  • Inspect relay: On the control board, inspect the fan relay for welded contacts. If stuck closed, the board will need repair or replacement.
  • Wiring check: Ensure no wires have been incorrectly bridged during previous repairs.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cooling Fan Thermostat / Main Control Board