Balay Low Flame / Poor Gas Flow

Gas burner flame is very weak or goes out when set to low.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked injector, Incorrect low‑flame adjustment, Low gas supply pressure, Faulty gas valve

How to Fix / Troubleshooting

Safety first: Turn off the burner and close the gas supply if you suspect a leak. Work in a well‑ventilated area.

  • Step 1 – Clean burner and injector: Remove burner parts and clean as described previously. If accessible, gently clean around the injector with a soft brush; do not insert hard objects into the jet.
  • Step 2 – Test other burners: If all burners are weak, the issue may be with gas supply pressure. Contact your gas provider or a technician.
  • Step 3 – Adjust minimum flame (technician): Remove the control knob and adjust the low‑flame screw on the gas valve using a small screwdriver, following Balay’s service instructions. Set the flame so it is stable and does not go out when turning quickly from high to low.
  • Step 4 – Check gas regulator: For LPG installations, verify that the correct regulator is installed and functioning.

Do not enlarge injectors to increase flame; this is unsafe and will cause improper combustion.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Gas Injector
Check Price on Amazon

We may earn a commission from links on this page.