F12
Blomberg
Communication Error Between Display and Power Board
F12 displayed; oven functions disabled or intermittent.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose harness between user interface board and power/EOC board, Faulty display board, Faulty main control board, Electrical noise or surge damage
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before removing the control console.
- Reseat connectors: Remove the console cover and locate the harness between the display/UI board and the main control/EOC. Unplug and firmly reconnect each connector.
- Inspect for damage: Look for burnt spots, cracked solder joints, or corrosion on both boards.
- Check harness continuity: Use a multimeter to verify that each wire in the harness has continuity end-to-end.
- Replace faulty board: If wiring is good and F12 persists, replace the UI/display board first. If still unresolved, replace the main control/EOC.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
User Interface (Display) Board
Check Price on Amazon