Blomberg No Power to Control / Main Power Failure

Range control panel is completely dead; no display or response.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker, Loose power cord connection, Burned terminal block, Blown internal fuse on control board, Failed main control board

How to Fix / Troubleshooting

Safety first: Turn off the breaker before inspecting the rear of the range. High voltage is present at the terminal block.

  • Check breaker: Verify the range breaker is not tripped. Reset if necessary.
  • Inspect power cord and outlet: Ensure the cord is plugged in securely and the outlet has correct voltage.
  • Check terminal block: Remove the rear cover and inspect the terminal block for burnt wires or melted plastic. Repair or replace as needed.
  • Internal fuse: Some Blomberg models have an internal fuse on the control board. Check and replace with the exact type if blown, but investigate the cause of the failure.
  • Replace control board: If power is present at the board but it remains dead, replace the main control/EOC.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Oven Control (EOC)
Check Price on Amazon