Brandt No Power / Main Supply Fault

Induction cooktop on Brandt range does not power on at all; no lights or display.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker, Blown internal fuse, Loose mains connection at terminal block, Faulty main filter or control board

How to Fix / Troubleshooting

Safety first: Ensure the breaker is off before opening any electrical covers.

Steps:

  • Check household breaker: Reset if tripped. If it trips again immediately, there may be a short circuit.
  • Verify outlet voltage: Use a multimeter to confirm correct voltage at the wall outlet or junction box.
  • Inspect terminal block: Remove the rear cover and check for loose or burnt connections. Tighten screws and repair any damaged wiring.
  • Internal fuse: Some Brandt models have an internal fuse on the filter board. Replace only with the same rating if blown, and investigate why it failed.
  • Control board: If power is present at the terminal block but the hob remains dead, the main control or filter board may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Terminal Block / Internal Fuse
Check Price on Amazon

We may earn a commission from links on this page.