Cooling fan runs continuously long after the hob has been turned off.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
User observation: It is normal for the fan to run for some minutes after use, but it should not run indefinitely.
User step: If the fan runs for more than 30–40 minutes after last use, switch off the hob at the mains for a few minutes and then back on.
Technician steps:
- Check the NTC temperature sensors on the heat sinks and coils for correct readings.
- Inspect the fan control relay or triac on the main control PCB for welded contacts.
- Verify correct wiring of the fan; it should be controlled, not permanently live.
Replace the control board or fan relay if it is stuck on.