Caple Intermittent Pan Detection / Power Modulation Fault

Induction hob clicks on and off rapidly and will not maintain a steady heat.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Warped or unsuitable pan, Dirty glass surface, Loose pan detection coil, Faulty induction power board

How to Fix / Troubleshooting

User steps:

  • Try a different, flat‑bottomed induction‑compatible pan.
  • Clean the glass and pan base thoroughly.
  • Ensure the pan is centred on the cooking zone and not overhanging excessively.

Technician steps (if problem persists with known good pans):

  • Inspect the pan detection coil and its mounting for looseness or damage.
  • Check the wiring harness to the induction power module for intermittent connections.
  • Replace the power module if internal faults are found.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Induction Coil Assembly