Grundig Power Limitation / Overload Protection

Induction zone on Grundig hob repeatedly cuts out or reduces power when using large pans or high settings.

Advertisements

Possible Causes

Power management group limit reached, Shared inverter for multiple zones overheating, Inadequate electrical supply, Poor ventilation under hob

How to Fix / Troubleshooting

Safety first: Ensure adequate ventilation around the hob and do not cover vents.

  • Reduce simultaneous load: Avoid running all zones at maximum power at the same time. Lower one or more zones to medium.
  • Check power sharing: Some Grundig hobs share power between paired zones; consult the manual to understand which zones are grouped.
  • Improve ventilation: Ensure the cabinet under the hob is not packed with items blocking airflow.

If power reduction occurs even with light use, a technician should check the power module and cooling system.

Advertisements

Repair Difficulty

Easy 2/5
Advertisements