E08
Hoover Current Limit / Power Management Fault

Hob shows E08 and shuts down when multiple zones are used simultaneously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect power sharing configuration, Faulty power management circuit on main board, Internal short drawing excessive current, Supply cable undersized or overheating

How to Fix / Troubleshooting

Safety first: Turn off the hob and isolate from mains. Overcurrent conditions can be hazardous.

  • Reduce load: After cooling, restore power and test using only one or two zones at medium power. If E08 does not appear, the issue may be related to power sharing or supply limitations.
  • Check installation: Have an electrician verify that the hob is wired with the correct cable size and breaker rating as per Hoover specifications.
  • Inspect for burning (technician only): A Hoover technician should inspect the main board and terminal block for signs of overheating or damaged tracks.
  • Replace faulty board: If the power management circuit is defective, the main power board must be replaced.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Power Board
Check Price on Amazon