F2
Miele Overtemperature Fault / Sensor Out of Range

Display shows F2; oven or cooktop may shut down or limit power; often associated with overheating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed oven temperature sensor (NTC), Shorted cooktop temperature sensor, Blocked cooling airflow around electronics, Faulty cooling fan for control compartment

How to Fix / Troubleshooting

Safety: Turn off power at the breaker and allow the appliance to cool completely before working near hot components.

  • Check for blocked vents: Verify that ventilation slots around the control panel and under the cooktop are not blocked by cabinetry, foil, or debris.
  • Inspect cooling fan: On ranges, remove the rear panel and confirm the control compartment cooling fan spins freely and is not obstructed. Replace if seized or noisy.
  • Test temperature sensor: Locate the oven temperature sensor (NTC) or cooktop sensor harness. Disconnect and measure resistance with a multimeter at room temperature; compare to Miele’s spec (typically around 1–1.1 kΩ at 25°C for many NTCs—check service data).
  • Check wiring: Inspect sensor wiring for burns, pinched insulation, or loose connectors at the control board.
  • Replace faulty sensor: If resistance is open, shorted, or far out of spec, replace the sensor. Clear the error by power cycling.

Warning: Do not bypass temperature sensors; this can create a fire hazard.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Temperature Sensor (NTC)
Check Price on Amazon