F9
Miele Mains Voltage / Power Supply Fault

F9 displayed; oven may not start or may shut down; sometimes associated with power supply issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect line voltage (too low or too high), Loose terminal block connections, Neutral or phase loss, Internal power supply failure on control board

How to Fix / Troubleshooting

Safety: Only qualified persons should measure live mains voltage. Always turn off power before tightening connections.

  • Check supply: Verify the correct voltage at the wall supply or junction box (e.g., 240 V split‑phase or 230 V single‑phase, depending on region and model).
  • Inspect terminal block: Remove the rear cover and inspect the mains terminal block. Tighten any loose screws and look for heat discoloration or melted plastic. Replace the block if damaged.
  • Check wiring: Confirm that L1, L2, and N (if used) are correctly connected per Miele wiring diagram.
  • Control power supply: If supply and terminal block are correct, the internal low‑voltage power supply on the main control may be faulty, requiring control module replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Mains Terminal Block
Check Price on Amazon