Miele No Power to Control / Internal Fuse Blown

Range clock and display on Miele unit are blank; oven and cooktop do not operate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped household breaker, Loose mains connection, Blown internal control fuse, Failed low‑voltage power supply on control board

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening the rear or top panels.

  • Check breaker: Verify the circuit breaker is on and not tripped. Reset if necessary.
  • Inspect terminal block: Confirm tight, undamaged connections at the mains terminal block.
  • Internal fuse: Some Miele controls have an internal fuse. Access the control board and test/replace the fuse with the exact same type and rating if blown.
  • Control board: If the fuse is good but no low‑voltage output is present, the control’s power supply is likely defective and the board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Electronic Control Module
Check Price on Amazon

We may earn a commission from links on this page.