Siemens Ignition Switch Stuck Closed / Moisture in Ignition System

Continuous clicking from gas burners even when all knobs are in OFF position

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Liquid spill under control knobs, Stuck or shorted ignition switch, Faulty spark generator module, Shorted ignition wiring

How to Fix / Troubleshooting

Safety first: Turn off all burners and unplug the cooktop or switch off the circuit breaker. Do not leave the appliance clicking continuously.

User actions:

  • Remove burner knobs and dry the area thoroughly if there was a recent spill or cleaning.
  • Allow the cooktop to air dry for several hours; a fan can speed this up.

Technician actions:

  • Test each ignition switch for continuity; a switch that remains closed when not pressed must be replaced.
  • Inspect ignition wiring for shorts to chassis.
  • If switches and wiring are good, replace the spark generator module.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ignition Switch Harness
Check Price on Amazon