E1
Siemens Overheating Protection / Internal Temperature Sensor Fault

Induction cooktop zone shuts off and displays E1 shortly after switching on

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked ventilation openings, Overheated electronics due to poor installation clearance, Faulty NTC temperature sensor on heat sink, Defective cooling fan

How to Fix / Troubleshooting

Safety first: Switch off the cooktop and allow it to cool for at least 30 minutes. Do not cover the ventilation openings.

User checks:

  • Ensure that air inlets and outlets under the worktop and in the cabinet are not blocked by drawers, insulation, or stored items.
  • Remove any objects stored directly under the cooktop that may obstruct airflow.
  • Verify that the cooktop was installed according to the Siemens installation manual (minimum ventilation clearances).

Technician checks:

  • Disconnect power at the breaker.
  • Remove the cooktop and inspect the cooling fan for free rotation and cleanliness. Clean dust from fan and heat sink.
  • Test the NTC temperature sensor on the heat sink with a multimeter for correct resistance vs. temperature.
  • Check wiring from the sensor to the power module for damage or loose connectors.
  • Replace the cooling fan or power module if they fail tests or show visible damage.

If E1 recurs immediately after cooling and ventilation correction, professional service is strongly recommended.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cooling Fan
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements