F2
Siemens Oven Overtemperature Fault

Range oven section (on a Siemens range) shows F2 and shuts off heating

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed oven temperature sensor (NTC), Shorted sensor wiring, Stuck relay on power board, Cooling fan failure in oven cavity

How to Fix / Troubleshooting

Safety first: Turn off the oven and allow it to cool. Disconnect power before accessing internal components.

User checks:

  • Ensure oven vents are not blocked by foil or pans.
  • Do not use aluminum foil to cover the entire oven base, as this can trap heat.

Technician checks:

  • Measure resistance of the oven temperature sensor at room temperature and compare with Siemens specs.
  • Inspect wiring from sensor to the oven control board.
  • Check the oven cooling fan for operation during heating cycles.
  • If the sensor and fan are OK, test the control board relays; replace the oven control module if relays are stuck.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements