Siemens Flame Supervision Device (Thermocouple) Failure

Gas burner ignites but goes out when knob is released

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty thermocouple, Misaligned thermocouple tip not in flame, Loose thermocouple connection at gas valve, Defective safety gas valve

How to Fix / Troubleshooting

Safety first: Always ensure the burner is off before disassembling parts. If you smell gas, close the gas supply and ventilate.

User checks:

  • Light the burner and hold the knob pressed for 10–15 seconds to allow the thermocouple to heat. If the flame still goes out, service is needed.
  • Ensure the burner cap is correctly positioned so the flame contacts the thermocouple tip.

Technician checks:

  • Inspect the thermocouple tip position relative to the flame; adjust if necessary.
  • Test thermocouple output (mV) when heated; replace if below specification.
  • Check the connection at the gas safety valve for tightness.
  • If a new thermocouple does not resolve the issue, replace the gas safety valve for that burner.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermocouple
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements