Siemens Ignition System Failure – No Spark

Gas burner will not ignite (no clicking sound, no spark at electrode)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective spark generator module, Broken ignition switch in burner knob, Loose or broken ignition wire, No mains power to cooktop ignition circuit

How to Fix / Troubleshooting

Safety first: Turn all burner knobs to OFF. If you smell gas, open windows, do not use electrical switches, and close the gas shutoff valve. Call a professional if the smell persists.

User checks:

  • Verify that the cooktop is plugged in and that the circuit breaker is on.
  • Try another electrical outlet with a small appliance to confirm power.
  • Check that burner caps and crowns are correctly positioned.

Technician checks:

  • Remove the knobs and test the ignition switches for continuity when pressed.
  • Access the underside and inspect the spark generator module and wiring to each electrode.
  • Replace any damaged ignition wires or cracked electrodes.
  • If no clicking is heard on any burner when a knob is turned, replace the spark generator module.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Spark Generator Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements