Induction cooktop displays E07 and shuts off when high power is selected on multiple zones.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: This involves live electrical measurements. Only a qualified person with a multimeter should perform voltage checks. Always turn off power before tightening connections.
Steps:
- Verify dedicated circuit: Confirm the cooktop is on a dedicated circuit with the correct breaker size and wire gauge as specified in the installation manual.
- Check terminal block: Turn off the breaker, remove the junction box cover or rear access panel, and inspect the terminal block. Tighten all lugs to the manufacturer-specified torque. Look for discoloration or melted insulation.
- Measure voltage: With power restored, measure line-to-line and line-to-neutral voltages at the terminal block. Compare to the rating plate (typically 240 V or 208 V). Significant deviation can trigger E07.
- Correct wiring issues: If voltage is low under load, consult an electrician to correct undersized wiring, loose connections in the home panel, or overloaded circuits.
- Control check: If supply voltage is correct and stable but E07 persists, the main control/power module may be misreading input voltage and require replacement.
Warning: Never operate the cooktop on an incorrect voltage or with loose connections; this can cause arcing, component failure, or fire.
Repair Difficulty
Required Part
We may earn a commission from links on this page.