Sub-Zero Low Flame / Simmer Adjustment Issue

Gas cooktop burner goes out on low setting or will not stay lit at simmer.

Advertisements

Possible Causes

Improperly adjusted simmer screw, Partially clogged burner ports, Low gas pressure

How to Fix / Troubleshooting

Safety first: Keep flammable materials away from the cooktop. Do not leave burners unattended while adjusting flame.

Steps:

  • Clean burner: Remove and clean the burner cap and head. Ensure all ports are clear, especially the small simmer ports.
  • Locate simmer adjustment: Remove the burner knob. Behind the valve stem, locate the small simmer adjustment screw (consult the service manual for exact location).
  • Adjust flame: Light the burner and turn it to the lowest setting. Using a small screwdriver, slowly turn the simmer screw until the flame is stable and just above the burner ports without going out.
  • Check gas supply: If flames are weak on all burners, have a gas technician verify supply pressure and regulator operation.

Note: Make small adjustments and allow the flame to stabilize before deciding if more adjustment is needed.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Burner Valve (Simmer Adjustment)
Check Price on Amazon