Sub-Zero Insufficient Cooling / Venting Issue

Range control panel gets very hot to the touch during oven use.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed cooling fan, Blocked oven vent, Missing or misinstalled insulation

How to Fix / Troubleshooting

Safety first: Turn off power and allow the oven to cool before removing panels. Hot surfaces can cause burns.

Steps:

  • Check vents: Ensure that the vent openings above or behind the door are not blocked by trim, foil, or objects.
  • Test cooling fan: During a bake cycle, the cooling fan should run. If it does not, test the fan motor and replace if faulty.
  • Inspect insulation: Pull the range out and remove rear or side panels to inspect insulation around the oven cavity. Replace or reposition any missing or displaced insulation per the service manual.

Warning: Excessive heat at the control panel can damage electronics and should be corrected promptly.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Cooling Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.