Summit Failed Infinite Heat Control Switch

Electric surface element heats only on high and cannot be controlled at lower settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn internal contacts in infinite switch, Shorted switch, Miswired replacement switch

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the control panel.

  • Compare behavior: Verify that other elements respond normally to their controls. If only one element is affected, suspect its switch.
  • Access switch: Remove the back panel behind the control knobs on your Summit range. Locate the infinite switch for the affected burner.
  • Inspect wiring: Confirm wires are connected to the correct terminals per the wiring diagram. Look for burned or loose connectors.
  • Replace switch: If wiring is correct and the symptom persists, replace the infinite heat control switch for that burner.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Infinite Heat Control Switch
Check Price on Amazon