E15
Candy Compressor Relay / Overload Protection Fault

E15 displayed; refrigerator may not cool; compressor relay clicks repeatedly or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective compressor relay on PCB, Stuck overload protector, High compressor start current due to mechanical wear, Poor electrical connections at compressor terminals

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before working at the rear. Beware of hot compressor surfaces.

E15 indicates a problem with the compressor start/overload protection.

  • Check ventilation: Ensure adequate space around the fridge and that condenser coils are clean to reduce compressor load.
  • Inspect start device: Remove the start relay/overload from the compressor and check for burn marks or melted plastic.
  • Test overload: With a multimeter, check continuity through the overload protector. An open circuit when cool indicates failure.
  • Replace start device: Install a new Candy-approved start relay/overload assembly if defective.
  • Compressor condition: If the new start device overheats or trips quickly, the compressor may be failing mechanically and require professional replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay / Overload Protector
Check Price on Amazon

We may earn a commission from links on this page.