E18
Candy Temperature Calibration / Sensor Range Error

E18 displayed; refrigerator may show incorrect temperatures or fail to adjust setpoints.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Out-of-range NTC sensor values, Incorrect sensor type fitted previously, Firmware calibration error, Wiring cross-connection between sensors

How to Fix / Troubleshooting

Safety: Disconnect power before testing sensors or wiring.

E18 is a temperature reading/calibration error.

  • Verify sensors: Check that the correct Candy NTC sensors are installed in fridge, freezer, and evaporator positions. Mismatched sensors can cause range errors.
  • Measure resistances: At a known temperature (e.g., 20°C), measure each sensor and compare values. Replace any that are significantly out of expected range.
  • Check wiring: Ensure sensor harnesses are not swapped between connectors on the PCB.
  • Control reset: After corrections, unplug for 10 minutes, then reconnect to allow the PCB to reinitialize.
  • PCB replacement: If all sensors and wiring are correct, the control board calibration may be corrupted and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Refrigerator NTC Sensors Set
Check Price on Amazon