E19
Candy Door Open Alarm Circuit Fault

E19 displayed; audible alarm may sound; doors appear closed but alarm persists.

Advertisements

Possible Causes

Misaligned door causing poor seal, Faulty door switch or reed sensor, Weak door magnet, Control board input error

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before adjusting switches or panels.

E19 is related to the door open detection system.

  • Check door alignment: Ensure the doors close fully and are level. Adjust hinges if necessary so the gasket contacts the cabinet evenly.
  • Inspect gasket: Look for twisted or damaged door seals that prevent full closure.
  • Test door switch: Manually operate the switch and observe if the interior light turns on/off (when briefly powered). Replace if faulty.
  • Magnet check: For magnetic reed systems, ensure the magnet in the door is present and correctly positioned.
  • PCB input: If hardware is fine, the PCB input circuit may be defective and require board replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Gasket and Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements