E20
Bissell Keypad / Power Button Error

Robot vacuum shows E20 and may not start due to a stuck or unresponsive power button.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Power button physically stuck, Spilled liquid causing button contamination, Faulty button switch on control panel, Damaged top control PCB

How to Fix / Troubleshooting

Safety first: Ensure the robot is off and disconnected from the dock.

  • Inspect button travel: Press the power button several times. It should move freely and click distinctly.
  • Clean around button: Use a slightly damp cloth to clean around the button area. Do not allow liquid to enter the unit.
  • Try app control: If the robot responds to app commands but not the physical button, the button switch is likely faulty.
  • If E20 persists: The top control panel or button PCB may need replacement. Install a new top control panel assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Top Control Panel Assembly
Check Price on Amazon

We may earn a commission from links on this page.