Rowenta Keypad / Button Panel Failure

Robot vacuum does not respond to start/stop button presses on the unit

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn start/stop button switch, Moisture under keypad, Disconnected keypad ribbon cable, Faulty top control PCB

How to Fix / Troubleshooting

Safety first: Turn the robot OFF and remove it from the dock.

  • 1. Try app control: If the robot responds to commands from the Rowenta app or remote, the main board is likely fine and the issue is with the physical buttons.
  • 2. Dry out: If the robot was recently cleaned with liquid, allow it to dry for 24–48 hours in a warm, dry place.
  • 3. Internal inspection: Remove the top cover to access the keypad PCB. Check that the ribbon cable is firmly seated.
  • 4. Replace keypad PCB: If the cable is secure but buttons still do not work, replace the top control / keypad PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Top Control / Keypad PCB
Check Price on Amazon

We may earn a commission from links on this page.