Rowenta Battery Capacity Degradation

Robot vacuum starts but shuts off after a few minutes of cleaning

Advertisements

Possible Causes

Aged lithium‑ion cells with reduced capacity, Battery not fully charging, High internal resistance in battery pack, Faulty battery management circuit

How to Fix / Troubleshooting

Safety first: Allow the robot to cool if it feels warm after shutdown.

  • 1. Full charge cycle: Place the robot on the dock and charge uninterrupted for at least 5 hours.
  • 2. Run‑down test: Start a full cleaning cycle and time how long it runs before shutting off. If runtime is significantly below the specification (e.g., less than 20–30 minutes), the battery is likely worn.
  • 3. Check charging contacts: Clean the robot and dock contacts to ensure efficient charging.
  • 4. Replace battery: Install a new Rowenta‑compatible lithium‑ion battery pack if runtime remains short.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Lithium-Ion Battery Pack
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements