E54
AEG
Motor Relay Sticking / Fault
Washer-dryer intermittently fails to spin or reverse tumble, E54 displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn or sticking motor direction relay on PCB, Pitted relay contacts, Overheated PCB around relay, Excessive motor current draw
How to Fix / Troubleshooting
Safety: Disconnect mains power before accessing the control board.
- Check motor load: Ensure the drum turns freely by hand and that bearings are not seized, which can overload the relay.
- Inspect PCB relays: On the AEG control board, locate the motor relays. Look for discoloration or heat damage.
- Replace PCB or relay: In most cases, the entire PCB is replaced. Skilled technicians may replace the individual relay.
Because this involves soldering and mains circuits, professional repair is advised.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board (AEG PCB)
Check Price on Amazon